Many manufacturers considering Warehouse Automation are not planning to build a new facility. They already have a warehouse, established production processes and a limited amount of space to work with. What they need to know is whether the existing building can accommodate an automated storage system without creating new problems elsewhere in the operation.

This is where Mini-FlyBox is worth evaluating.

Its rack-based design integrates horizontal travel and vertical level-changing functions, making it suitable for compact tote storage applications. DELIECN Mini-FlyBox supports configurations up to 12 m high, with an aisle configuration as narrow as 860 mm and a maximum tote load of 50 kg.

Those characteristics can be useful when floor space is limited. But a compact system is not automatically suitable for every existing warehouse. The building structure, usable height, inventory requirements and connections to picking and production all influence whether a proposed installation will work.

The first step is therefore to assess the warehouse as an operating facility, not simply as an empty space available for racks.

Start with the Usable Height, Not the Building Height

A warehouse may appear tall enough when measured from the floor to the roof, but that measurement alone does not establish the usable storage height.

Beams, columns, lighting, fire protection equipment, ventilation systems and other overhead services can affect the space available for the rack structure and equipment. The height needed for installation, maintenance and safe operation must also be considered.

Mini-FlyBox is designed for warehouse applications up to 12 m high. Whether that height can be used effectively in an existing building depends on the actual layout and the required system configuration.

A site assessment should establish the lowest relevant overhead obstruction, the available installation envelope and any building features that constrain rack placement. It should also check whether the proposed storage arrangement leaves sufficient room for the required inbound and outbound interfaces.

This is particularly important when converting an existing warehouse, because the usable height may be considerably less than the nominal building height suggests.

1.jpg

A Narrow Aisle Helps, but It Does Not Solve Every Space Constraint

Mini-FlyBox supports an aisle configuration as narrow as 860 mm. For facilities where floor space is limited, this provides a useful starting point for planning a compact storage layout.

However, aisle width is only one part of the overall footprint.

The complete installation also needs space for the rack structure, inbound and outbound handling, picking stations, equipment access and maintenance. If totes need to move between the storage system and several production or packing areas, the connecting routes must be included in the layout.

Existing columns and fixed equipment can further restrict the available arrangement. In some buildings, a compact rack may fit into the storage area but leave insufficient space for the picking process or the movement of finished orders.

For this reason, the design should consider the entire material flow before the rack dimensions are finalized.

The objective is not simply to fit more storage into the same building. It is to use the available space without compromising the way goods enter, leave and move through the warehouse.

Check the Floor and Building Structure Before Finalizing the Layout

An existing floor should not be assumed suitable simply because it has supported conventional warehouse operations.

Automated Storage equipment introduces specific requirements relating to structural loading, floor condition, levelness and installation tolerances. The relevant requirements depend on the proposed rack and equipment configuration.

The assessment should establish the floor's condition and load-bearing capacity, together with the structural requirements of the planned installation. Column positions, expansion joints and other fixed building features should also be checked against the proposed rack arrangement.

Where the existing conditions do not meet the design requirements, corrective work may be necessary before installation.

These checks are best completed early. Discovering a structural or floor constraint after the rack layout has been finalized can force changes to the storage design, installation schedule or project budget.

A proper feasibility assessment identifies these constraints before they become construction problems.

Plan the Picking Process Before Deciding Where the System Goes

The storage system is only one part of a warehouse retrofit. The more important question is how the system will support the operation after installation.

Consider a warehouse where operators currently walk between storage locations to collect small components. Introducing Mini-FlyBox may reduce the need to search for items manually, but the benefits depend on how the retrieved totes reach the operators and what happens after picking.

The layout must account for the position of the picking workstation, the arrival of requested totes, order confirmation and the return or onward movement of containers.

Depending on the project, the transfer interfaces may use conveyors, AMRs or a combination of handling methods. The right choice depends on the distances involved, the number of destinations and the frequency of material movement.

A warehouse that serves several production lines may need a different arrangement from one that primarily handles e-commerce orders or spare parts.

The design should therefore begin with the actual picking and replenishment process. Once that process is understood, the storage system can be positioned to support it rather than forcing the existing operation to adapt to an unsuitable layout.

Consider How the System Will Connect to Existing Operations

A retrofit rarely starts with a completely new logistics process. Existing warehouses may already use ERP, MES or WMS software, barcode identification, conveyors and production-side material handling.

Mini-FlyBox needs to fit into this environment.

WMS manages inventory, storage locations and warehouse tasks, while WCS coordinates the execution of tasks by the automated equipment. Where existing business systems are retained, the project must define how product information, inbound instructions, picking requests and task confirmations are exchanged.

The integration scope depends on the customer's existing software and the responsibilities assigned to each system. It should be established before commissioning rather than left until the physical installation is complete.

The same principle applies to material-handling interfaces. If the automated warehouse needs to receive goods from an existing production line or deliver totes to an established packing area, the transfer points and operating sequence must be designed together.

This helps prevent a situation in which the storage equipment works correctly but the wider warehouse still depends on manual workarounds.

Account for Installation, Maintenance and Daily Operation

A compact layout must still leave sufficient access for installation and maintenance.

The project team needs to consider how the equipment will be brought into the building, where components can be accessed for servicing and how maintenance work can be performed without creating unnecessary disruption to other warehouse activities.

Electrical infrastructure and equipment power supply also need to be checked. Mini-FlyBox uses conductor rail power supply, so the electrical design and installation arrangement must be coordinated with the rack layout and operating requirements.

Environmental conditions are another consideration. DELIECN Mini-FlyBox supports a specified operating temperature range of −25°C to +45°C, but the suitability of a particular installation still depends on the actual environment and the complete system configuration.

Where a warehouse operates under unusual temperature, dust or other demanding conditions, these factors should be identified during the assessment rather than assumed to be covered by the standard configuration.

The aim is to ensure that the proposed system can be installed, operated and maintained within the constraints of the existing facility.

When Is an Existing Warehouse Suitable for Mini-FlyBox?

There is no single measurement that determines whether an existing warehouse is suitable.

The building needs sufficient usable height and a workable rack footprint. The floor and structure must meet the installation requirements. There must also be enough space to connect the storage system to the intended picking and material-handling process.

Inventory characteristics matter just as much. Tote dimensions and weights must fall within the selected configuration's limits, while the required storage capacity and retrieval workload must be achievable with an appropriate system design.

In some facilities, the existing building may accommodate Mini-FlyBox with limited layout changes. In others, structural constraints, insufficient transfer space or a mismatch between the storage requirements and the available building envelope may require a different configuration or a broader redesign.

The decision should follow a site assessment and an evaluation of the operating requirements, rather than a general promise that the system can fit into any warehouse.

What to Prepare for a Retrofit Assessment

A preliminary assessment becomes more useful when the manufacturer can provide an existing warehouse layout, building height and relevant structural information. Inventory data should include the number of SKUs, tote dimensions, loaded tote weights and the quantities that need to be stored.

The operating requirements are equally important. Daily inbound and outbound volumes, peak retrieval demand, picking arrangements and the destinations served by the warehouse help establish the required system capacity and material flow.

Information about existing ERP, MES or WMS platforms, conveyors and production interfaces also helps define the integration scope.

Not every detail needs to be finalized before the first discussion. Where information is unavailable, it can be identified as an item for further investigation. The important point is to distinguish confirmed site conditions from assumptions that still need verification.

With these inputs, the project team can assess whether Mini-FlyBox is suitable, identify potential constraints and determine what further engineering work is needed before a detailed proposal is prepared.

Make the Existing Building Work for the Operation

Retrofitting an existing warehouse is not simply a matter of replacing conventional racks with automated equipment. The building, storage layout, picking process and software interfaces all need to work together.

Mini-FlyBox offers a compact tote storage architecture for applications where space utilization is an important consideration. Its suitability for a particular facility, however, depends on the usable building envelope, structural conditions, inventory profile and required material flow.

For manufacturers, the most useful first step is to establish what the existing warehouse can accommodate and what the operation needs from the new system. That assessment provides a sound basis for deciding whether Mini-FlyBox is the right fit and how the installation should be designed.

A successful retrofit is not the one that fits the most equipment into the building. It is the one that makes better use of the available space while supporting the warehouse's actual storage, picking and replenishment requirements.

Lila

Lila

Lila is a skilled marketing professional with extensive expertise in the field of logistics automation. With a keen understanding of intralogistics, she plays a pivotal role in promoting the company's advanced robotics technologies and end-to-end automation solutions. Lila is passionate about......
Previous What Are the Top China Shuttle Robot Types in 2026?